product-img
  • small-img

PFM920-6U

305m Outdoor UTP CAT6 Cable

> 305.0 m (1000 ft)/carton outdoor UTP CAT6, power over Ethernet, compatible with one cable.
> High-purity Oxygen-Free Copper conductor material.
> Customized MDPE outer sheath; meet ANSI/TIA 568-C.2 flame retardant class certified
> Environmentally friendly and all materials used are RoHS compliant.


  • Caractéristiques
  • Accessoires
  • Téléchargement
  • Conductor

    Material

    Oxygen free copper (99.97% purity)

    Diameter

    0.57 mm ± 0.02 mm(0.02"± 0.0007")

    American Wire Gauge

    23AWG

    Insulation

    Material

    HDPE

    Min. Average Thickness

    0.21 mm(0.0082")

    Diameter

    1.02 mm ± 0.06 mm(0.04"± 0.0023")

    Color

    8-core, Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown

    Rip Cord

    Material

    Polyester

    Specification

    500D

    Separator

    Material

    PE

    Dimension

    Translucent 4.5 × 0.4 mm(0.03")

    Wrap

    Material

    Polyester tape (transparent)

    Dimension

    W: 25mm±2mm*T: 0.026mm±0.02mm(W: 0.98"±0.07"*T: 0.0010"±0.0007")

    Sheath

    Material

    MDPE

    Min. Average Thickness

    0.7 mm(0.03")

    Diameter

    6.2 mm ± 0.4 mm(0.2441"± 0.0157")

    Color

    Black

    Electrical

    Max. DC Resistance of a Single Conductor

    7.35Ω/100 m

    Min. Insulation Resistance

    5000MΩ·km

    Max. DC Resistance Unbalance

    2% (pair intra), 4% (pairs inter)

    Dielectric Strength

    No breakdown with 1KV DC for 1 min

    Transmission

    Characteristic Impedance

    100 ± 15Ω

    Near End Cross Talk

    ≥39.30 dB/100 m@250 MHz

    Max. Attenuation

    32.8 dB/100 m@250 MHz

    Return Loss

    ≥17.3 dB/100 m@250 MHz

    Mechanical

    Tensile Strength

    Sheath≥12 MPa, insulation≥16 MPa

    Elongation at Break

    Sheath≥350%, insulation≥300%

    Installation Bending Radius

    >8 times of outer cable diameter

    Conductor Elongation at Break

    ≥15%

    Environmental

    Shrinkage of Insulation

    ≤5%

    Color Migration Resistance of Insulation

    No migration

    Low Temperature Bending Test

    No cracking after the test

    Heat Shock Test

    No cracking after the test

    Operation Temperature

    –20°C to +60°C (–4°F to 140°F)

    Installation Temperature

    0°C to +50°C (32°F to 122°F)

    Storage Temperature and Humidity

    –10°C to +40°C (14°F to 104°F), <60% (RH)

    Packaging

    Length

    305m (1000.66 ft) ± 2 m (6.56ft)

    Packaging Dimensions

    476mm × 476 mm × 222 mm (18.74" × 18.74" ×8.74") (L × W × H)

    Packaging Method

    305 m (1000.66 ft) a carton, one protection carton with 2 cartons inside

    Net Weight

    11.7kg±0.6kg (25.79 lb±1.32lb)

    Gross Weight

    12.7kg±0.6kg (27.99 lb±1.32lb)

    Executive Standard

    Executive Standard

    ANSI/TIA 568-C.2