product-img
product-img
product-img
product-img
product-img
  • small-img
  • small-img
  • small-img
  • small-img
  • small-img

ITRTSC-036B-HS EoL-L

Traffic Signal Controller

> Supports configuring start sequence.
> Detection and report of temperature and humidity.
> Display and control through LCD screen.
> Supports two-intersection control, waiting area configuration and display, and more.
> Supports repeated running of phase, and different phase parameters for different cycle schemes can be separately configured.
> Monitoring and display of input voltage, input current, and overall power consumption. Supports low voltage downgrade.
> Reversible lane control, suitable for tidal lanes and reversible lanes.
> Supports configuring default light color and special status, ideal for road that cannot enter within defined time and roads requiring slow passing.
> Connects to traffic enforcement cameras, coils, pedestrian pushbuttons and more to collect traffic flow data and offer integrated solution of traffic signal control.
> Cableless linking control.
> Update through network, USB, or TF card; alarm and lighting linkage when door of the signal controller is opened or closed
> In actuated control, the controller can stop timing different barriers (used for separating the rings) at the same time.


  • Specifications
  • Accessories
  • Download
  • Performance

    LCD

    LCD screen: Supports displaying time, phase direction, phase number, phase countdown, phase total time; searching for fault and software information; configuring cycle scheme, control mode, time and date, and network

    Flasher

    Standard hardware flasher, independent on program control (only for models with flasher)

    Channel

    3 output boards, supporting 36 channels

    Phase

    16 parent phases and 16 overlap phases. Supports repeat running of parent phase, meeting requirements of repeat timing in a cycle and independent parameter settings

    Signal Group

    12 groups

    Cycle Scheme

    Up to 54 cycle schemes

    Pretimed Control

    Up to 112 daily schemes, 48 pretimed periods, 30 weekly schemes, 30 daily dispatch schemes, and 30 special dispatch schemes

    Pedestrian Crossing

    Input and output of up to 8 pedestrian pushbuttons

    Signal Control Mode

    Manual control, pretimed control, cableless link control, actuated control, pedestrian crossing coordination control

    Actuated Control

    Up to 16-channel coils and 64-channel traffic enforcement cameras. Two detecting devices (include camera, coil, and more) can be used for detecting one lane

    Manual Control

    Manual control and remote control through host computer or central platform to meet on-site requirements

    Change of Control Modes

    Natural change between manual control and automatic control (pretimed control, actuated control, and more)

    Cableless Linking Control

    Yes. Coordination control is realized by GPS time synchronization and setting offset

    Special Mode Control

    Yes

    Two-intersection Control

    Yes

    Temporary Scheme

    Supports configuring or clearing temporary schemes through platform

    Waiting Area Configuration

    Yes

    Default Light Color

    Default light colors include all red, flashing yellow, light off, and red flashing. Default light color displays when no phase is running in a scheme or no channel is configured

    Special Status

    Supports special status control of traffic lights, such as all red, yellow flashing, light off, and red flashing

    Countdown Timer

    Self-learning, pulse, and RS-485 communication countdown timers. Supports setting baud rate when using RS-485 communication countdown timer

    Time Synchronization

    NTP, GPS, network sync, manual time adjustment

    Hot Standby of Main Control Board

    Yes

    Phase Parameters

    Separately set parameters of phase for cycle schemes and repeated phase. Each cycle scheme can be set with different phase parameters

    Signal Control Duration

    Adjustable

    Auto Phase Timing

    When adjusting a cycle, set the total cycle length, and the phases will be timed automatically according to the split (the ratio of phase time and cycle length in a cycle)

    Failure Detection

    Degradation mechanism in case of green conflict and light fault; independent hardware yellow flashing control; fault information upload and search

    Door Monitoring

    Monitors door of the controller, and report door status (opened or closed) to platform

    Network Control

    Communicates with host computer or central platform through network; supports setting temporary scheme and special tasks on platform

    Information Security

    Identity authentication, control order verification, update verification of operation parameters, and broadcast storm protection

    Parameter Setting

    Supports setting control parameters on PC client and remote server

    Upgrade

    Network upgrade, USB/TF card upgrade

    Lighting

    Gives out light when door of the signal controller is opened or closed

    Voltage Monitoring

    Monitors input voltage

    Temperature and Humidity Monitoring

    Yes

    Low Voltage Downgrade

    Reports temperature and humidity to platform

    Startup Sequence

    Yes

    Port

    Control Switch

    1 main power switch, 1 controller switch, 1 signal light control switch, 1 flasher switch (only for models with flasher), 1 socket switch, 1 three-pin socket, and 1 lighting switch

    Power Input

    1

    Network

    3 RJ45 10/100M Ethernet ports: 1 on the main control board, and 2 on the communications control board

    RS-232

    8

    RS-485

    4

    USB

    2

    TF Card

    2

    GPS

    2

    Alarm Input

    14 (pedestrian pushbutton input port included)

    Alarm Output

    10 (pedestrian pushbutton output port included)

    General

    Power Supply

    220V AC±30%/110V AC±20%, 50 Hz±2 Hz

    Insulation Resistance

    ≥10MΩ

    Voltage Resistance

    1500V AC, 50Hz (1500V AC, 50Hz voltage is applied between the power electrode or other conductive circuits connected to the power electrode and easily accessible parts such as cabinets and installation casing)

    Overall Power Consumption

    ≤60W (no load)

    Drive Power

    ≤550W

    Operating Temperature

    –40°C to +80°C (–40°F to +176°F)

    Operating Humidity

    10%–95% (no condensation)

    Protection Grade

    IP54

    Protection

    Mains lightning protection; network lightning protection; electromagnetic immunity (no electrical failure in electromagnetic disturbance environments such as electrostatic discharge, fast electrical transient bursts, surges, and short-term voltage interruptions); waterproof (passed rain test. The signal controller works normally during and after the test, and there is no water seepage or accumulation inside the signal controller); dustproof (during and after the dust test, the signal controller works normally, and there is no large amount of dust inside the signal controller); corrosion (the signal controller works normally after the salt spraying test, and there is no serious corrosion of metal components such as the signal controller casing and internal rack); passed vibration test and steel ball impact test

    Dimensions

    Without antenna cover: 450.0 mm × 300.0 mm × 780.0 mm (17.73'' × 11.82'' × 30.71'') (L × W × H)
    With antenna cover: 450.0 mm × 300.0 mm × 789.9 mm (17.73'' × 11.82'' × 31.48'') (L × W × H)

    Net Weight

    50.0 kg (110.23 lb)

    Gross Weight

    65.0 kg (143.30 lb)

    Certification

    NTCIP compliance

    Installation

    Floor-standing