product-img
  • small-img

PFM920I-6U-C-100

UTP CAT6 Cable

> 100 m (328 ft)/carton UTP CAT6, power over Ethernet, compatible with one cable

> High-purity oxygen-free copper conductor material

> Customized PVC outer sheath; CE CPR Eca flame retardant class certi fied

> Top-notch Quality Commitment for 10 Years

  • Specifications
  • Accessories
  • Download
  • Conductor

    Material

    Oxygen free copper (99.97% purity)

    Diameter

    0.57 mm ± 0.01 mm (0.0224"±0.0004")

    American Wire Gauge

    23AWG

    Insulation

    Material

    HDPE

    Min. Average Thickness

    0.21 mm (0.0083")

    Diameter

    1.0 mm ± 0.1 mm (0.0394"±0.004")

    Color (4 Pairs)

    Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown

    Separator

    Material

    PE

    Specification

    Translucent 4.5 mm × 0.4 mm (0.1772" ± 0.0157")

    Rip Cord

    Material

    Polyester

    Specification

    500D

    Sheath

    Material

    PVC

    Min. Average Thickness

    0.5 mm (0.0197")

    Diameter

    6.3 mm ± 0.3 mm (0.2480"±0.0118")

    Color

    White

    Electrical

    Max. DC Resistance of a Single Conductor

    7.5Ω/100 m

    Min. Insulation Resistance

    5000MΩ·km

    Max. DC Resistance Unbalance

    2% (pair intra), 4% (pairs inter)

    Dielectric Strength

    No breakdown with 1kV DC for 1 min

    Transmission

    Characteristic Impedance

    100 Ω ± 15 Ω

    Near End Cross Talk

    ≥39.30 dB/100 m @250 MHz

    Max. Attenuation

    33 dB/100 m @250 MHz

    Return Loss

    ≥17.3 dB/100 m @250 MHz

    Mechanical

    Tensile Strength

    Sheath≥9 MPa, insulation≥16 MPa

    Elongation at Break

    Sheath≥100%, insulation≥100%

    Installation Bending Radius

    >8 times of outer cable diameter

    Conductor Elongation at Break

    ≥8%

    Environmental

    Shrinkage of Insulation

    ≤5%

    Color Migration Resistance of Insulation

    No migration

    Sheath Tensile Strength and Elongation at Break after Aging

    ≥6.3 MPa, ≥100%

    Low Temperature Bending Test

    No cracking after the test

    Heat Shock Test

    No cracking after the test

    Operating Temperature

    –20°C to +60°C (–4°F to 140°F)

    Installation Temperature

    0°C to +50°C (32°F to 122°F)

    Storage Temperature and Humidity

    –10°C to +40°C (14°F to 104°F), <60% (RH)

    Security

    Vertical Fire Propagation Test

    Comply with IEC 60332-1-2

    Packaging

    Cable Length

    100.0 m (328.08 ft) ±1 m (3.28 ft)

    Inner Carton Dimensions

    286 mm × 119 mm × 289 mm

    (11.26" × 4.69" × 11.38") (L × W × H)

    Net Weight

    4.2 kg ± 0.3 kg (9.26 lb±0.66 lb)

    Gross Weight

    4.5 kg ± 0.3 kg (9.92 lb±0.66 lb)

    Packaging Dimensions

    595 mm × 310 mm × 270 mm

    (23.43" × 12.20" × 10.62") (L × W × H)

    Packaging Method

    100 m/carton, 4 inner cartons in one package

    Compliance

    Executive Standards

    ISO/IEC 11801-1-2017, IEC 61156-5-2009

    Certification

    Certification

    CPR Eca