product-img
  • small-img

PFM923I-6UN-C

305m UTP CAT6 LSZH CPR E Cable

> 305 m (1000 ft)/carton UTP CAT6, power over Ethernet, compatible with one cable

> High-purity oxygen-free copper conductor

> Customized PVC outer sheath; CE CPR Eca flame retardant class certified

> 10-year warranty


  • Specifications
  • Accessories
  • Download

  • Conductor

    Material

    Oxygen free copper (99.97% purity)

    Diameter

    0.53mm ± 0.01 mm

    Insulation

    Material

    HDPE

    Min. Average Thickness

    0.21 mm

    Diameter

    0.95 mm ± 0.1 mm

    Color (4 Pairs)

    Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown

    Separator

    Material

    PE

    Specification

    Translucent 4.5 × 0.4 mm

    Rip Cord

    Material

    Polyester

    Specification

    500D

    Sheath

    Material

    LSZH

    Min. Average Thickness

    0.5 mm

    Diameter

    6.0 mm ± 0.3 mm

    Color

    White

    Electrical

    Max. DC Resistance of a Single Conductor

    8.7 Ω/100 m

    Min. Insulation Resistance

    5000MΩ·km

    Max. DC Resistance Unbalance

    2% (pair intra), 4% (pairs inter)

    Dielectric Strength

    No breakdown with 1KV DC for 1 min

    Transmission

    Characteristic Impedance

    100 ± 15Ω

    Near End Cross Talk

    ≥39.30 dB/100 m@250 MHz

    Max. Attenuation

    34.8 dB/100 m@250 MHz

    Return Loss

    ≥17.3 dB/100 m@250 MHz

    Mechanical

    Tensile Strength

    Sheath≥10 MPa, insulation≥16 MPa

    Elongation at Break

    Sheath≥125%, insulation≥300%

    Installation Bending Radius

    >8 times of outer cable diameter

    Conductor Elongation at Break

    ≥10%

    Environmental

    Shrinkage of Insulation

    ≤5%

    Color Migration Resistance of Insulation

    No migration

    Sheath Tensile Strength and Elongation at Break after Aging

    ≥8 MPa, ≥100%

    Low Temperature Bending Test

    No cracking after the test

    Heat Shock Test

    No cracking after the test

    Operation Temperature

    –20°C to +60°C (–4°F to 140°F)

    Installation Temperature

    0°C to +50°C (32°F to 122°F)

    Storage Temperature and Humidity

    –10°C to +40°C (14°F to 104°F), <60% (RH)

    Security

    Vertical Fire Propagation Test

    Comply with IEC 60332-1-2

    Packaging

    Cable Length

    305.0 m (1000.66 ft) ± 1.5 m (4.92 ft)

    Inner Carton Dimensions

    416.0 mm × 412.0 mm × 220.0 mm (16.38" × 16.22" × 8.66") (L × W × H)

    Packaging Method

    305.0 m (1000.66 ft) a carton, one carton with 2 inner cartons 

    Net Weight

    ≥10.5 kg (23.15 lb)

    Gross Weight

    ≥11.5 kg (25.35 lb)

    Compliance

    Executive Standards

    Q/DXJ 067-2019, EN50575-2014

    Certification

    Certification

    CPR Eca

    Transmission Characteristics

    (100 m at 20°C) (328.08 ft at 68°F)

    Frequency (MHz)

    Phase delay ≤ ns

    IL ≤ dB

    TCL≥ dB﹡

    EL TCTL≥ dB﹡

    NEXT ≥ dB

    PS NEXT ≥ dB

    1

    n/s

    n/s

    50.0

    35.0

    n/s

    n/s

    4

    552.0

    4.0

    44.0

    23.0

    66.3

    63.3

    8

    547.0

    5.6

    41.0

    16.9

    61.8

    58.8

    10

    545.0

    6.4

    40.0

    15.0

    60.3

    57.3

    16

    543.0

    8.1

    38.0

    10.9

    57.2

    54.2

    20

    542.0

    9.0

    37.0

    9.0

    55.8

    52.8

    25

    541.0

    10.1

    36.0

    7.0

    54.3

    51.3

    30﹡

    540.6

    11.0

    35.2

    5.5

    53.1

    50.1

    31.25

    540.0

    11.3

    35.1

    n/s

    52.9

    49.9

    62.5

    539.0

    16.3

    32.0

    n/s

    48.4

    45.4

    100

    538.0

    21.0

    30.0

    n/s

    45.3

    42.3

    200

    537.0

    30.7

    27.0

    n/s

    40.8

    37.8

    250

    536.0

    34.8

    26.0

    n/s

    39.3

    36.3

    Frequency (MHz)

    EL FEXT ≥ dB

    PS EL FEXT ≥ dB

    RL ≥ dB

    Delay skew ≤ ns

    Zc(Ω)

    1

    n/s

    n/s

    n/s

    n/s

    n/s

    4

    56.0

    53.0

    23.0

    45.0

    100±15

    8

    49.9

    46.9

    24.5

    10

    48.0

    45.0

    25.0

    16

    43.9

    40.9

    25.0

    20

    42.0

    39.0

    25.0

    25

    40.0

    37.0

    24.3

    30﹡

    38.5

    35.5

    23.8

    31.25

    38.1

    35.1

    23.6

    62.5

    32.1

    29.1

    21.5

    100

    28.0

    25.0

    20.1

    200

    22.0

    19.0

    18.0

    250

    20.0

    17.0

    17.3

    Note:

    Executive standard for the above parameters: Q/DXJ 067-2019

    "n/s"=Not Specified

    "﹡"=Unless otherwise customer stated the test results default to not shown in test report but comply with standard